{"product_id":"k220-2v-brewing-system","title":"K220 2V Brewing System – 225L Two-Vessel Stainless Brewhouse","description":"\u003cp\u003e\u003cstrong\u003eReal output. Real stainless. No proprietary architecture.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BrewTaurus K220 2V is a 225 L two-vessel stainless brewing system: separate mash and boil vessels, 7 kW heating, dual MP40 pump hydraulics and a counterflow chiller. A modular stainless platform for serious-volume brewing — not an automated brewhouse, not plug-and-play, but a system you control end to end.\u003c\/p\u003e\n\u003cp style=\"background:#fff6ed;border-left:4px solid #e08a00;padding:10px 14px;border-radius:6px;font-size:14px;\"\u003e\u003cstrong\u003eMade to order (pre-order).\u003c\/strong\u003e We build in monthly production batches — contact us for the current lead time before ordering.\u003c\/p\u003e\n\u003ch3\u003eDesigned operating range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal kettle capacity: 225 L · recommended batch (into fermenter): 150–190 L\u003c\/li\u003e\n\u003cli\u003eMax practical knockout: 195–205 L · minimum efficient batch: ~100–110 L\u003c\/li\u003e\n\u003cli\u003eDesigned to operate in the 150–190 L range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeating, grain \u0026amp; mash\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2× 3.5 kW tri-clamp elements (7 kW total) · 2× Inkbird C236T (16A EU plug) · two independent 16A circuits\u003c\/li\u003e\n\u003cli\u003eHeat-up (170 L, 15→100°C): ≈55–70 min · rolling boil at 180 L, ~6–8%\/h evaporation\u003c\/li\u003e\n\u003cli\u003eGrain capacity: 50–72 kg (max ~75 kg with careful recirc) · mash thickness 2.5–3.2 L\/kg\u003c\/li\u003e\n\u003cli\u003eExample: 60 kg × 2.8 L\/kg → ~168 L mash\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHydraulics, cooling \u0026amp; cleaning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2× MP40 65W pumps (continuous-duty) — simultaneous mash recirc + sparge, whirlpool + transfer prep, CIP recirculation without reconfiguring hardware\u003c\/li\u003e\n\u003cli\u003eStainless manifold routing · 11× tri-clamp quick-connects · full sanitary 1.5\" TC architecture\u003c\/li\u003e\n\u003cli\u003eCounterflow wort chiller (single-pass), designed for 150–190 L — single-pass to 18–22°C at 10–15°C groundwater; ~18–28 min knockout (180 L)\u003c\/li\u003e\n\u003cli\u003eCIP head via 1.5\" lid port · no welded dead-end cavities · all components serviceable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBrewhouse-efficiency example\u003c\/h3\u003e\n\u003cp\u003eTarget 12°P Pale Ale (~1.048 OG), 180 L into fermenter → ~22.6 kg extract needed. Base malt potential ~80% (dry). Implied efficiency: 38 kg → ~74%, 40 kg → ~71%, 42 kg → ~67%. For planning assume ~70%.\u003c\/p\u003e\n\u003cp style=\"background:#fff6ed;border-left:4px solid #e08a00;padding:10px 14px;border-radius:6px;font-size:14px;\"\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e two independent 16A circuits, stable water supply for the chiller, flat load-bearing floor (filled system ≈300–360 kg). Standalone Inkbird control keeps failure points low; a centralised control panel is in development and will integrate without replacing vessels.\u003c\/p\u003e\n\u003cp style=\"background:#eef5ef;border:1px solid #cfe4d4;padding:10px 14px;border-radius:6px;font-size:14px;\"\u003eCompare the \u003ca href=\"https:\/\/brewtaurus.com\/products\/k220-1v-brewing-system\"\u003eK220 1V\u003c\/a\u003e or full \u003ca href=\"https:\/\/brewtaurus.com\/products\/k220-3v-brewing-system\"\u003eK220 3V\u003c\/a\u003e · See all \u003ca href=\"https:\/\/brewtaurus.com\/collections\/brewing-systems\"\u003eBrewing Systems\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e1V vs 2V vs 3V — which K220 configuration\u003c\/h3\u003e\n\u003cp\u003eSame K220 vessel volume, three workflows. One-vessel is the simplest footprint; two- and three-vessel add dedicated mash\/boil (and HLT) for parallel steps and faster brew days. Your configuration is highlighted.\u003c\/p\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;background:#f3f5f3;\"\u003eConfig\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;background:#f3f5f3;\"\u003eVessels\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;background:#f3f5f3;\"\u003eWorking batch\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;background:#f3f5f3;\"\u003eHeating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;background:#f3f5f3;\"\u003ePumps\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;background:#f3f5f3;\"\u003eChiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003eK220 1V\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e1 (mash+boil)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e60–195 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e7 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e1× MP40\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;background:#eef5ef;font-weight:700;\"\u003eK220 2V\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;background:#eef5ef;font-weight:700;\"\u003e2 (mash, boil)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;background:#eef5ef;font-weight:700;\"\u003e150–190 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;background:#eef5ef;font-weight:700;\"\u003e7 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;background:#eef5ef;font-weight:700;\"\u003e2× MP40\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;background:#eef5ef;font-weight:700;\"\u003eCounterflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003eK220 3V\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e3 (HLT, mash, boil)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e60–200 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e14 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e2× MP40\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003eCounterflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical summary\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;\"\u003eSystem type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003eTwo-vessel (mash + boil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;\"\u003eNominal capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e225 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;\"\u003eWorking batch range\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e150–190 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;\"\u003eHeating \/ pumps\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003e7 kW (2× 3.5 kW) · 2× MP40 65W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003eCounterflow, single-pass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;font-weight:600;\"\u003eMaterial \/ architecture\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e6e6e6;padding:8px 10px;\"\u003eSS304 · full stainless tri-clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"BrewTaurus.com | Brewing Technology","offers":[{"title":"Default Title","offer_id":55335726022990,"sku":"000570","price":6999.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/9810\/6309\/files\/373A2672-6894-4270-99E4-B03FE199A8EA_1_105_c.jpg?v=1771085154","url":"https:\/\/brewtaurus.com\/en-cz\/products\/k220-2v-brewing-system","provider":"BrewTaurus.com | Brewing Technology","version":"1.0","type":"link"}